This is not a DIY product. All Rights Reserved. However, when I power on the AquaLink PDA, it shows the water temp is 120 degrees. Replace the Power Cord When you Replace the Cell, Replacing Old Square Jandy PLC700/1400 Cell, AquaPure Resets to 35% Everytime it is Powered On, AquaPure and PureLink Tri-Sensor Adapter Installation Kit Manual, Jandy AquaPure, PureLink & Nature Fusion Soft Workbook, https://www.troublefreepool.com/threads/need-intelliflo-and-jandy-aquapure-1400-folks.254612/post-2226671, https://www.troublefreepool.com/threads/plc1400-and-r0452400-compatible.260746/#post-2280305, https://www.troublefreepool.com/threads/six-month-old-jandy-plc1400-smoking-melting-rubber-wire-connector.198600/post-1752937, https://www.jandy.com/-/media/zodiac/global/downloads/h/h0325600.pdf, https://www.troublefreepool.com/threads/aquapure-cycle-time-wiki-correction.264622/#post-2321916, http://viewer.zmags.com/publication/1a29b06c#/1a29b06c/892, https://www.troublefreepool.com/threads/when-did-jandy-declare-war-on-diy.176586/post-1558946, https://www.troublefreepool.com/threads/jandy-old-square-salt-cell-replacement.201262/, https://www.troublefreepool.com/threads/jandy-aquapure-1400-error-120.236117/, https://www.troublefreepool.com/threads/aquapure-1400-receiving-error-code-123.46288/post-387518, https://www.troublefreepool.com/threads/jandy-aquapure-plc-700-not-producing-chlorine.220478/post-1929929, https://www.troublefreepool.com/threads/will-a-new-water-temp-sensor-fix-this-aquapure-swg-scenario.243392/, https://www.troublefreepool.com/threads/jandy-pda-wasnt-displaying-aquapure-info.194647/post-1715658, https://www.troublefreepool.com/threads/aquapure-keeps-resetting-to-chlorine-rate-35-from-pool-pump-timer.197670/post-1743853, https://www.troublefreepool.com/threads/jandy-power-center-transformer-replacement-aquapure.194422/, https://www.troublefreepool.com/wiki/index.php?title=Jandy_AquaPure_SWG&oldid=5928, PURE700 - 0.625 lb./24 Hr. Stainless steel is better adapted to resist salt than Galvanised steel. A member found that the new part fit perfectly with the same mounting holes. As for information, the internet is a great thing. Make sure that the salt is very well mixed by brushing thoroughly at least 5 times. Note that the center prong is on the cell where the power cord connects to the cell. Find a Dealer AquaPure Downloads Document ID SL5801CE Jandy APUREM AquaPure Salt Generator Power Center, Brand new returned unit - Never installed just opened, Create a Saltwater Oasis in Your Backyard, Automatic self-cleaning feature ensures consistent operation and extended lifespan of the cell, Exclusive Tri-Sensor technology provides reliable electronic water flow detection to sustain maximum performance, even at very low flow rates, Digital salinity read-out for accurate salt-level indication, Flow, temperature and status readings provide instant feedback on the current operation, When combined with PureLink power centers, AquaLink and AquaPure work together for the ultimate in pool sanitizing and remote operation convenience, Seamless communication with AquaLink Control systems enables easy monitoring of salt levels and convenient, precise sanitizer output settings, Note: The salt cells are sold separately Installation by a qualified pool professional required. Changes to Aquapure settings made on Aqualink will not show on the Aquapure and the chlorine% will be 0. If you have a No-Flow error try resetting the circuit breaker and re-calibrating the tri-sensor before you consider replacing it. In this thread, the amperage of the 1400 cell tests at about 5.6 amps, and the amperage of the 700 cell should test at about 2.8 amps.[11]. Power Center Compatible with Pentair IntelliChlor Pool, APPLIAFIT O-Ring Compatible with Jandy Zodiac R0357800 for CL, CV, DEL & DEV Series Filters (2-Pack), Tier1 Pool & Spa Filter Cartridge | Replacement for Dimension One 1561-00, Pleatco PDO75-2000, FC-3059, C-7367, Aladdin 17541 and More | 75 sq ft Pleated Fabric Filter Media, POOLPURE PDM28 Spa Filter Replaces Aquarest Dream Maker 461273 Hot Tub Filter, 2 Pack, SpaO2 Swimming Pool Aerators - Set of 2, ABS Injection Molding, Fit 1-1/2 FIP/MIP Threaded Return outlets, MAX Depth 19.7, Raise pH Without Changing Alkalinity, Crystal Clear Water, Less Chemicals, 1996-2023, Amazon.com, Inc. or its affiliates, Zodiac APUREM AquaPure Foundation Power Center Pack Replacement for Zodiac Jandy AquaPure PureLink Cell Kit. Quantity. * Pricing, promotions and availability may vary by location and at lesliespool.com. 120 is low current. The Jandy Versa Plumb System delivers the highest energy efficiency through its innovative design that maximizes hydraulic integrity. Apple and the Apple logo are trademarks of Apple Inc., registered in the U.S. and other countries. It is ok to startup the chlorinator when there is a little bromide in the pool. While the salt shouldn't have any effect on the person if a small amount is swallowed, please keep in mind that the water is chlorinated and chlorine should not be consumed. 2023 Zodiac Pool Systems LLC - All rights reserved. Jandy switched to a 3-port cell design to aid in cleaning and plumbing flexibility and no longer makes 2-port cells. Jandy Zodiac AquaPure PLC1400 PLC 1400 Saltwater Cell Kit AQUA PURE 352 8 offers from $1,209.92 Product Description This control box cover is designed to use with Zodiac AquaPure plastic control center model APURE700. (Take pool water sample to Pool Professional). Less work = longer life. All other forms of chlorine (tablets, powder, liquid, etc.) Either a short wait or a reboot resolve this. Jandy Zodiac AquaPure PLC1400 PLC 1400 Saltwater Cell Kit AQUA PURE. This issue is with the trisensor, which is a separate part that installs in the cell. I bought one of these units from another vendor three years ago. Very happy with seller. If still too low, Super Chlorinate with outside source. Do Not Sell or Share My Personal Information. 2023 Zodiac Pool Systems LLC - All rights reserved. Or just the control box? You need the Aquapure system with the control box and cell. The AquaPure salt-water chlorine sanitizing systems uses salt water to deliver water sanitation by generating chlorine. See Section 5, Operating Instructions of the owner's manual. Water conditioning salt pellets take longer to dissolve. These clowns should join the Not reliable at all and have had problems starting about 1 month after installation. Do I still need to use granular chlorine with my Salt water chlorinator? The Jandy AquaPure APUREM salt-water chlorine sanitizing systems use salt water to deliver high-performance water sanitation with uncompromised performance, reliability and hydraulic efficiency. Jandy AquaPure Control Center Parts |6 parts Frequently Purchased AquaPure Sanitizer Bottom Control Box Decal - R0404400 6 in stock $65.70 Add To Cart AquaPure Transformer - 115/230 Volts - R0481400 12 in stock $434.61 Add To Cart Control Box Cover, Pure1400 - R0403200 Allow 7-10 Days to Ship $185.91 Add To Cart Pure700 Control Box Cover - R0403100 The salt under the effect of electrolysis, is transformed into sodium hypochlorite, a disinfectant. This site is protected by reCAPTCHA and the Google. Remove and clean flow/temp/salinity sensor and reinstall. Remove and clean flow/temp/salinity sensor contacts. . Drop in the Best When You Replace the Rest. This is related to the serial com connections that are used. No Flow indicator stays on continuously. Please try again. Field switchable to power all PureLink, ClorMatic and Nature2 Fusion Soft cell kits, LCD monitoring of chlorine production, cell modes, salinity, temperature, water flow and diagnostics. Please use a different way to share. Get 1 point for every $1 spent. The PLC1400 cell is Jandy P/N R0452400. Item No. Perks can be redeemed online, in store or in the Leslies app. It's usually cheaper to buy the Aquapure 1400 cell kit that comes with the cell, trisensor and power cord vs. buying the parts separately. In the case of a salt water chlorinator, the salt may damage the stone along the water line over time (crystallization). Use Up and Down arrow keys to navigate search results. The aquapure power center is an electrical panel that is installed at the equipment pad. Add salt as described in Section 4.7 of the owner's manual. When a FREEZE CONTROLLER is used on pump equipment and the chlorinator is run through the winter, turn the CHLORINE PRODUCTION down to 10 - 20%. Reviewed in the United States on June 20, 2014. Most common is the center pin.[9]. The problem is that the O-rings can leak, which creates a corrosive mix of water, salt, hydrogen gas and chlorine gas. App Store is a service mark of Apple Inc. Google Play is trademark of Google, Inc. All other trademarks referenced herein are the property of their respective owners. ORP / External Control Interface 2. It may not display this or other websites correctly. Error posting question. Control CenterThe control center converts AC electrical current to a low voltage DC current which is required by the cell to perform the electrolysis. More Details. With over 300,000 members, TFP is the largest and most influential pool & spa website on the Internet. It displays the salt level in PPM on the display, and you can set the production rate (0-100%) on the LCD display, or you can integrate the system with a Jandy controller as I did. Need to, Your zip code will help us to provide you with the most up-to-date delivery information. Brief content visible, double tap to read full content. However, the Jandy PLC700 cell kit (for pools up to 12,000 gallons) and the PLC1400 (with a 40,000 gallon capacity) kit contain new cells as well as all the necessary accessories to switch a 2-port setup to the new design.[8]. Report PoolGate Gold Supporter TFP Guide Jun 7, 2017 7,748 Damascus, MD Pool Size 29000 One method is an additional PVC union after each end of the cell. The Jandy AquaPure salt-water chlorine purifying systems use salt water to deliver high-performance water purification with uncompromised performance, reliability and hydraulic efficiency. The AquaPure does not have a flow switch, it has a flow sensor, which is a heated probe and and unheated probe and it works on the same principle as "wind chill".[1]. Select Options. 2) Order your Power Center. Refer to Maintenance Procedure for acid wash cleaning. JavaScript is disabled. inground with iAqualink remote control. The audible alarm is described on page 34 of the Jandy Pro Series AquaPure/PureLink Power Center and Cell Kit | Installation and Operation Manual.[4]. We will contact you as soon as this product is available. I have upgraded the circuits boards as per Zodiac's support advice and they only made the problem less prevalent. The AquaPure cells can be controlled by the AquaPure user interface inside the control/power center or by the Aqualink automation systems. Currently, Jandy has part R0481400 which is the round transformer. See Section 2, Figures 2a, 2b, and 2c of the owner's manual. See Section 4.5 of the owner's manual. Jandy AquaPure Power Pack Features: Field switchable to power all PureLink, ClorMatic and Nature2 Fusion Soft cell kits 120V or 240V electrical connections LCD monitoring of chlorine production, cell modes, salinity, temperature, water flow and diagnostics Precision output adjustments Note: Pool Pump and Control Center to AquaPure Must be Wired to Turn On and Off Together AquaPure Control Center 115 / 230 VAC Electrical Supply Return to Pool From Pool Cell Pump Flow / Salinity Sensor Filter Heater To Drain (Backwash) Salt for Pool A q u a P u r e Options List 1. . We have never winterized before. Test salinity. Pricing and offers are subject to change. If the salinity is above 4.0 gpl, the unit will cut off and give error code 145 (High Salinity). Zodiac Jandy iAquaLink 2.0 Wireless Network Pool Control Interface Sys. A 121 error can occur for a number of different reasons: dirty cell, damaged cell, bad cell cable, low salt level, cell wearing out due to age, or damaged power supply. The manual says that the unit can be damaged, which could void the warranty. Sign up for regular updates and to get the Jandy Drop-In Replacement Guide for model comparisons, dimensions, and more. contain additives. With the AquaPure 1400, the reading is in grams per liter, which is the same as 1,000 ppm. If one of them is rotted away, it's time for a new cell and cord. App Store is a service mark of Apple Inc. Google Play is trademark of Google, Inc. All other trademarks referenced herein are the property of their respective owners. The PDA uses the pool's temperature sensor. You can usually see evidence of a leak when you know to look for it. The TRI sensor only pertains to the swg. Zodiac R0467600 Printed Circuit Board Power Interface Replacement for Select Zodiac Jandy Pool and Spa Power Centers. If the unit does not read 2.8 gpl for salinity, then the unit has been recalibrated. If the unit is not correctly installed you may get severe electrical shock or you may fry the system. So yes, they are reading two different temps. PLASTIC CONTROL CENTER, MODELS 700 & 1400, PARTS - BIG DIPPER, ECLIPSE, TOTAL ECLIPSE, COMPLETE HIGHCAPACITY BROMINE & CHLORINE FEEDERS, KREEPY E-Z VAC & KREEPY KADET ACCESSORIES, ANTHONY "APOLLO RECTANGULAR FILTER GRIDS, ANTHONY "APOLLO RECTANGULAR FILTER GRIDS, AMERICAN PRODUCTS 5 & 8 POSITION TOP MOUNT, SPA DRAIN & ON/OFF VALVES FOR GARDEN HOSE, STANDARD HEATER UNION COMPONENTS - 1", 200 SERIES TYPHOON JETS - SCALLOPED, 2" FACE, 300 SERIES TYPHOON JETS - SCALLOPED, 3" FACE, 400 SERIES TYPHOON JETS - SCALLOPED, 4" FACE, 500 SERIES TYPHOON JETS - SCALLOPED, 5" FACE, RETRO FITTING LEN GORDON & OTHER CONTROLS, SPLASH PAK - 16, 18.5, & 24 SAND FILTERS, SPLASH PAK - 16, 18.5, & 24 SAND FILTERS, SPLASH PAK - 16, 18.5, & 24 SAND FILTERS, ANTHONY "APOLLO RECTANGULAR FILTER GRIDS, 200 SERIES TYPHOON JETS - SCALLOPED, 4" FACE, JANDY AQUAPURE | CONTROL BOX, PURE700 | R0402900, JANDY AQUAPURE | UNION NUT, 2" BLACK | R0412500, JANDY AQUAPURE | SALINITY METER | R0475300, JANDY AQUAPURE Ei | TS CONTROL PCB ASSY | R0512300, JANDY AQUAPURE | SPOOL PIECE, 2" BLACK UNIONS W/2803-009 | R0412800, POLARIS OZONATORS | 110/220V FOR UP TO 40,000 GALLONS | PZVII-2 | Discontinued, PENTAIR | HC-3330 HOUSING W/ 2098-0 | R172437, Pool and Spa Parts Depot | Swimming Pool Supplies. Thanks for identifying the water temperature sensor that will also have to be replaced. The controller will periodically change the direction of the cell current in order to eliminate the layers of scale that deposit on the electrode plates. Full content visible, double tap to read brief content. Guess we will this year. Would recommend it to anyone needing a replacement or installinf for the first time. We are sorry. The item you are trying to purchase is currently out of stock.Please enter your name, email, and phone number below. 2 - Screws, Power Interface. Creating an account will enroll you in our Pool Perks loyalty program. This is why changing this parameter is reserved for the pool professional. Jandy AquaPure 1400 Chlorine Generator Quick Specs View Detailed Specs Power: 1.25 lbs/day 90-Day / 1 Year Limited Warranty 8000 Hours Rated Lifespan 40000 Gallons Max Capacity Description Reviews Specs Controls Cell Warranty "The Heavy-Duty Standard for Maximum Performance" Manufacturer SKU: 6967+. This could be a defective automatic timer or pump switch or loose connection at the automatic timer or pump switch. 3.9 out of 5 stars 35. We had to replace the filter and pump body! Any new postings here are unlikely to be seen or responded to by other members. It should use the Air temperature sensor. It is possible his sensors are reversed. 2023 Leslies Poolmart Inc. Were sorry we missed you; we look forward to assisting you soon. Turn the chlorinator off or reduce the chlorine production percentage to zero. We paired it with the APUREM. Please obtain a google maps API key and put it in Site Preferences! A member had the problem of his Aquapure resetting to 35% every time it was powered on by the timer. Remove obstruction and/or clean cell. The sensor connects to the same spot. Pool and Spa Parts Depot | Swimming Pool Supplies. Being relatively adept, I chose to install this myself. Salt level may decrease after a heavy rain, backwashing, refilling, draining or excessive splash out. Add salt to pool, 3.0 gpl to 3.5 gpl. Wichita Falls, TX. Rely on its sturdy design and simple features to create your saltwater oasis. Look at the label on the CPU for the firmware revision. The Jandy AquaPure salt-water chlorine sanitizing systems use salt water to deliver high-performance water sanitation with uncompromised performance, reliability and hydraulic efficiency. Apple is not a participant or sponsor of this promotion. Drop in the Best When You Replace the Rest. Salt only needs to be added when necessary. Car & Truck Safety & Security Accessories, DEWALT DCCS620B 20V MAX Cordless Li-Ion 12 in. Please try again. Sitemap | For a better experience, please enable JavaScript in your browser before proceeding. It's cheaper to go with another salt Unit came with panel knocked out and the circuit board was bad. The prongs are sealed by O-rings and a compression plate held down by two screws. Determine the amount of salt necessary to add from an appropriate chart. Jandy Aquapure Control Center. Reviewed in the United States on April 8, 2017. Jandy has the Jandy SP3P Dummy Cell Cleaning Kit that includes everything you need to remove, clean, store, and/or bypass your Jandy AquaPure 3-Port Salt Cell. Turn on pump. Backwash or partially drain pool and dilute with fresh water until salinity returns to 3.0 gpl to 3.5 gpl. Using genuine Jandy factory replacement parts helps to ensure the ongoing quality and reliability of our products. In fairness to Zodiac/Jandy, they feel that a pool professional should do this. The Sensor Interface Module is weatherproof and should be left outside (Fig 3a) of the power center enclosure (Fig 3b). View More Details. Disconnect the flow salinity temp sensor from the front board. You are dealing with 240 Volts and electrical circuits. If more chlorine is needed, activating the Boost mode will override this cold water feature allowing chlorine production for 24 hours of operation. While still holding the two front board test buttons press the Pool Temperature key (D). The 700 cell has half the number of plates as the 1400 cell. eschewing the conventional role in traditional architectural hierarchies, this project acts as a catalyst to an overcrowded favela by bringing in social infrastructure and a connection between top . FREE delivery Feb 16 . For all your hard to find pool and spa parts, including above ground spa parts, , Copyright 2023 Pool and Spa Parts Depot. (567 gm/24 Hr.). A common reason for the cell failing and getting error codes 120, 121 or 123 is one or more of the pins corroding and separating from its plate. Thanks, Problem solved. The PureLink Power Centers combine all the features of the AquaLink Power Centers and AquaPure water purification electronics in one box. $1,079.00. Does the Freeze Protect mode use the reading from the tri-sensor or the pool temperature sensor? We could have gotten by with the PLC700 but this We made the decision to go to a salt water pool system. See Section 5, Operating Instructions of the owner's manual. Ensure there is no loss of pump prime or clogged strainer baskets. 20 points earns $1 Pool Perks reward. Verify salinity with Myron L meter calibrated for NaCl, titration test units, or other salt meters. If the readings are correct then the board is O.K. Zodiac / Jandy R0476400 Replacement Sensor Kit for AquaPure PLC700 / PLC1400. Older Power Centers use a rectangle transformer P/N T1005 that is no longer available. The cartridge must be replaced. This applies to the Jandy AquaPure and the Nature2 FusionSoft as they are sister products. An optional "Spool" Piece (sold separately) used to be available to replace the cell during winterizing or cell maintenance. The cell cannot be repaired even though the plates may have life left in them. For urgent questions, you can reach us directly at Am I correct in assuming that the box contains the internal components such as the control, A: Free shipping for many products! That is NOT what you have. You have 3 temp sensors. There are numerous sites that have detailed information about the install. Being relatively adept, I chose to install this myself. Super Chlorinate Pool. 1 - Mounting Bracket, User Interface, APUREM. Recheck. Jul 7, 2021. The LCD should read 2.8 gpl*. Brand new! See Section 6 of the owner's manual, User Maintenance Instructions. Yes. ZODIAC is a registered trademark of Zodiac International, S.A.S.U., used under license. Your panel uses the tri-sensor in the saltwater chlorine generator. If its 02110A10 or 01220A15, you use program A, otherwise you use program B on the in-line module on the trisensor cord. Aqualink prevents the Aquapure system from proper operation without a functioning water temperature signal from the Aqualink stand alone water temperature sensor, regardless of what the SWG flow sensor says. Check that ribbon cable is fully inserted into connector. You must log in or register to reply here. So it looks like it is good, but the water temp sensor is bad. ORP / Freeze Control Unit 3 . Is there only 1 water temperature sensor? The Jandy AquaPure salt-water chlorine sanitizing systems use salt water to deliver high-performance water sanitation with uncompromised performance, reliability and hydraulic efficiency. The control center is connected with the pool circulation pump electrical source so that the electrolytic cell can only operate when the pool pump is on. A letter will be included with each new Tri-Sensor ALERTING Installers about the new installation instructions. Will there be any harm if someone swallows salt water in a salt chlorinated pool? Natural stone can be visually altered over time. It measures temperature, salinity and flow. See also, Section 6.4, Flow/Temp/Salinity Sensor Cleaning, Step 4 of the owner's manual. Brush down the affected walls and follow the directions in Section 5.4.1 of the owner's manual, Shocking. I chose the Zodiac PLC1400 to pair with it. The LCD should read 91 F or 33 C . Boost 24 Hour 100% Chlorine Production Cycle. They are sold as a kit.[2]. I chose the Zodiac PLC1400 to pair with it. A separate communication will follow . (Use sodium chloride only). Cell trisensor senses temperature, salinity and flow. The remaining bromide in the pool will produce a white emulsion (chemical reaction). 2023 Zodiac Pool Systems LLC - All rights reserved. The mineral purifier cartridge may have ruptured. When replacing the cell, it's important to replace the power cord so that the connections are clean and the resistance is minimized.[3]. [14] After discussions with a Jandy representative it was determined the problem was a bad board. We evaluated 6535 medical consults of intoxication cases involving prescription and over-the-counter drugs in 2001. Had to call a pool guy. No instructions contained w/unit. It is being practiced by thousands of pool owners just like you. There were instructions included, but they were not as comprehensive as you would really need. This piece has been discontinued and is no longer available. That can be from low salt, low water temperature, a bad power cord, cell plates corroded or loose power pins. The system will display the salinity reading, press the up arrow to increase the reading and the down arrow to decrease the reading. Decrease the chlorine production rate adjustment button (arrow button A). The PureLink DC Cord is Jandy P/N R0402800. Polarity will change every 3 hours. Then adjust pH to within the range 7.4-7.6. I've had a Jandy Aquapure 1400 since I opened the pool 4 years ago, and it's in the process of dying. 624537. Balance the water to recommended levels in Section 4.5 of the owner's manual. High salt concentration above 4.0 gpl may damage the power center. All rights reserved. veggiebenz; Aug 8, 2022; Salt Water Chlorine Generators (SWG) Replies 2 . Sorry, we were unable to perform your search at this time. JANDY AQUAPURE PLASTIC CONTROL CENTER, MODELS 700 & 1400 JANDY AQUAPURE | CONTROL BOX, PURE1400 | R0403000 Categories POOL PARTS SPA PARTS CHEMICAL FEEDER CLEANERS FILTERS FILTER ELEMENTS FILTER VALVES FITTINGS & UNIONS HEATERS LIGHTS PILLOW PLEATCO PLUMBING VALVES PUMPS SKIMMERS SPA AIR BLOWERS SPA FITTINGS SPA PACK CONTROL COMPONENTS To avoid clogging the filter or damaging the control center and pump, do not add salt through the skimmer, main drain, or surge tank. Very happy with this controller. Find many great new & used options and get the best deals for E1 Jandy PLC1400 AquaPure 3-Port Salt Water Pool System at the best online prices at eBay! Jandy makes the Purelink Power Center that combines the Aqualink and Aquapure controls in one cabinet. It uses 240V and 50/60hz Export. Note: Pool Pump and Control Center to AquaPure Must be Wired to Turn On and Off Together AquaPure Control Center 115/230VAC Electrical Supply Return to Pool From Pool Cell Pump Flow / Salinity Sensor Filter Heater To Drain (Backwash) Salt for Pool A q u a P u r e Options List 1.